	<title>Sense-Ware Industrial Detectors | Alco Automation Pte Ltd</title>
	<atom:link href="https://alco-automation.com/product-category/flame-and-gas-detection-systems/flame-detectors/sense-ware-industrial-flame-detectors/feed/" rel="self" type="application/rss+xml" />
	<link>https://alco-automation.com</link>
	<description>Developing unique capabilities in engineering systems, providing solutions and integrating quality instrumentation since 1994.</description>
	<lastBuildDate>Mon, 13 Jan 2020 01:28:57 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.1</generator>

<image>
	<url>https://alco-automation.com/wp-content/uploads/2018/07/cropped-alcologo-32x32.png</url>
	<title>Sense-Ware Industrial Detectors | Alco Automation Pte Ltd</title>
	<link>https://alco-automation.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Sense-Ware 109 IR3 Flame Detector</title>
		<link>https://alco-automation.com/product/sense-ware-109-ir3-flame-detector/</link>
		
		<dc:creator><![CDATA[alcoauto]]></dc:creator>
		<pubDate>Tue, 27 Aug 2019 03:59:40 +0000</pubDate>
				<guid isPermaLink="false">https://alco-automation.com/?post_type=product&#038;p=389</guid>

					<description><![CDATA[The SENSE-WARE IR3 flame detectors utilizes a microprocessor for sophisticated electronic signal analysis. The sensors must exceed their alarm threshold to initiate a fire alarm. The triple IR flame detector uses an additional alarm criterion: the analysis of the flame flicker-frequency. The infrared IR3 flame detector has good false alarm rejection capabilities.

Features : 

- Suitable for heavy- and light Hydrocarbons such as Gasoline, Diesel, Methanol and Ethanol
- The IR3 flame detector is resistant to artificial- and sunlight
- Automatic sensor test
- IR3 flame detectors are suitable for indoor and outdoor applications
- CPR/EN54-10 certified
- FM class 3260 approved
- ATEX certified: II 3G  Ex nA IIC T4 Gc, II 3D Ex tc IIIC T 71°C Dc IP65, ambient temp.: -25° to +70°C
- cFMus class 3611 (Nonincendive, Class I, II and III, Div 2), ambient temp.: -25° to +70°C
- California State Fire Marshal (CSFM) listed]]></description>
										<content:encoded><![CDATA[The SENSE-WARE IR3 flame detectors utilizes a microprocessor for sophisticated electronic signal analysis. The sensors must exceed their alarm threshold to initiate a fire alarm. The triple IR flame detector uses an additional alarm criterion: the analysis of the flame flicker-frequency. The infrared IR3 flame detector has good false alarm rejection capabilities.

Features : 

- Suitable for heavy- and light Hydrocarbons such as Gasoline, Diesel, Methanol and Ethanol
- The IR3 flame detector is resistant to artificial- and sunlight
- Automatic sensor test
- IR3 flame detectors are suitable for indoor and outdoor applications
- CPR/EN54-10 certified
- FM class 3260 approved
- ATEX certified: II 3G  Ex nA IIC T4 Gc, II 3D Ex tc IIIC T 71°C Dc IP65, ambient temp.: -25° to +70°C
- cFMus class 3611 (Nonincendive, Class I, II and III, Div 2), ambient temp.: -25° to +70°C
- California State Fire Marshal (CSFM) listed]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Sense-Ware 185 UV Flame Detector</title>
		<link>https://alco-automation.com/product/sense-ware-185-uv-flame-detector/</link>
		
		<dc:creator><![CDATA[alcoauto]]></dc:creator>
		<pubDate>Tue, 27 Aug 2019 03:57:23 +0000</pubDate>
				<guid isPermaLink="false">https://alco-automation.com/?post_type=product&#038;p=387</guid>

					<description><![CDATA[The SENSE-WARE UV (Ultraviolet) Flame Detector utilizes a microprocessor for sophisticated electronic signal analysis. The UV flame detector is suitable for indoor and outdoor applications, such as fume hoods and hydrogen storages. Because of its non-corrosive housing it is suitable for indoor industrial areas were corrosion may play a role. UV (Ultraviolet) energy is emitted by almost every fire; both hydrocarbon and non- hydrocarbon fires. The Ultraviolet Flame Detector will alarm to Arc Welding.

Features : 

- Sensitive to virtually all fires including Hydrogen Flames
- The UV flame detector is resistant to artificial- and sunlight
- Automatic sensor test
- Ultraviolet flame detectors are suitable for indoor and outdoor applications
- CPR-EN54-10 certified
- FM class 3260 approved
- ATEX certified: II 3G  Ex nA IIC T4 Gc, II 3D Ex tc IIIC T 71°C Dc IP65, ambient temp.: -25° to +70°C
- cFMus class 3611 (Nonincendive, Class I, II and III, Div 2), ambient temp.: -25° to +70°C
- California State Fire Marshal (CSFM) listed

]]></description>
										<content:encoded><![CDATA[The SENSE-WARE UV (Ultraviolet) Flame Detector utilizes a microprocessor for sophisticated electronic signal analysis. The UV flame detector is suitable for indoor and outdoor applications, such as fume hoods and hydrogen storages. Because of its non-corrosive housing it is suitable for indoor industrial areas were corrosion may play a role. UV (Ultraviolet) energy is emitted by almost every fire; both hydrocarbon and non- hydrocarbon fires. The Ultraviolet Flame Detector will alarm to Arc Welding.

Features : 

- Sensitive to virtually all fires including Hydrogen Flames
- The UV flame detector is resistant to artificial- and sunlight
- Automatic sensor test
- Ultraviolet flame detectors are suitable for indoor and outdoor applications
- CPR-EN54-10 certified
- FM class 3260 approved
- ATEX certified: II 3G  Ex nA IIC T4 Gc, II 3D Ex tc IIIC T 71°C Dc IP65, ambient temp.: -25° to +70°C
- cFMus class 3611 (Nonincendive, Class I, II and III, Div 2), ambient temp.: -25° to +70°C
- California State Fire Marshal (CSFM) listed

]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Sense-Ware 210 UV/IR Flame Detector</title>
		<link>https://alco-automation.com/product/sense-ware-210-uv-ir-flame-detector/</link>
		
		<dc:creator><![CDATA[alcoauto]]></dc:creator>
		<pubDate>Tue, 27 Aug 2019 03:54:56 +0000</pubDate>
				<guid isPermaLink="false">https://alco-automation.com/?post_type=product&#038;p=384</guid>

					<description><![CDATA[The SENSE-WARE UV/IR Flame Detector is a combination of a UV- and IR- flame detector which utilizes a microprocessor for sophisticated electronic signal analysis. The IR part of the flame detector has an additional alarm criterion: the analysis of the flame flicker- frequency. The UV and the IR sensor must both exceed their alarm threshold to initiate a fire alarm. The UV/IR Flame Detector has good false alarms rejection capabilities because the UV and the IR sensor do not share false alarm sources. The UV/IR Flame Detector can therefore be applied in areas where single UV or IR flame detectors could potentially cause false and/or unwanted alarms.

Features : 

- Sensitive to virtually all fires including Hydrogen Flames
- Resistant to artificial- and sunlight
- Automatic sensor test
- Suitable for indoor and outdoor applications
- CPR-EN54-10 certified
- FM class 3260 Approved
- ATEX certified: II 3G  Ex nA IIC T4 Gc, II 3D Ex tc IIIC T 71°C Dc IP65, ambient temp.: -25° to +70°C
- cFMus class 3611 (Nonincendive, Class I, II and III, Div 2), ambient temp.: -25° to +70°C
- California State Fire Marshal (CSFM) listed]]></description>
										<content:encoded><![CDATA[The SENSE-WARE UV/IR Flame Detector is a combination of a UV- and IR- flame detector which utilizes a microprocessor for sophisticated electronic signal analysis. The IR part of the flame detector has an additional alarm criterion: the analysis of the flame flicker- frequency. The UV and the IR sensor must both exceed their alarm threshold to initiate a fire alarm. The UV/IR Flame Detector has good false alarms rejection capabilities because the UV and the IR sensor do not share false alarm sources. The UV/IR Flame Detector can therefore be applied in areas where single UV or IR flame detectors could potentially cause false and/or unwanted alarms.

Features : 

- Sensitive to virtually all fires including Hydrogen Flames
- Resistant to artificial- and sunlight
- Automatic sensor test
- Suitable for indoor and outdoor applications
- CPR-EN54-10 certified
- FM class 3260 Approved
- ATEX certified: II 3G  Ex nA IIC T4 Gc, II 3D Ex tc IIIC T 71°C Dc IP65, ambient temp.: -25° to +70°C
- cFMus class 3611 (Nonincendive, Class I, II and III, Div 2), ambient temp.: -25° to +70°C
- California State Fire Marshal (CSFM) listed]]></content:encoded>
					
		
		